Compliant with current regulations
The C.M.F. module controls motor speed and stops by reading the residual voltage on the stator windings.
The C.M.F. carries out two operations:
RV1 “failure” relay intervention
• by tripping the motor stop relay if real time is shorter than nominal time;
• by de-energising the relay when the set time is exceeded if real time is longer than nominal time.
The failure relay is tripped if a fault concerning the motor stop relay is detected or if the connections taking the return voltage from the stator windings are cut.
RV2 “no motor movement” relay intervention
by continuously comparing voltage at terminals and sending a signal as soon as the speed either approaches or reaches zero (motor stop).
by continuously comparing voltage at terminals and sending a signal as soon as the speed either approaches or reaches zero (motor stop):
√ motor dimensions,
√ residual induction,
√ rpm.
During deceleration, the C.M.F. controls return voltage, which is directly measured in proportion to speed.
√ Power supply: 24V. 50Hz + 15%.
√ Intake power: 5VA.
√ Max. measurable voltage: 500V ~ 780V=.
√ Measurable circuit impedance: 700 KOHM.
√ Motor stop nominal calibration: +/- 0.02V.
√ Stop control time: +/- 0.1 -10s.
√ Relay contacts: 2SC 5A. 250V.
√ Working temperature range: -10 +55°C.